financing Special Offers Call Us Book Online

Cary, NC HVAC & Electrical

green-stars

Professional HVAC & Electrical Solutions For Cary Homeowners

Cary families have trusted us with their heating, cooling, and electrical work since 2005, and we've built that trust by showing up when we say we will and doing quality work at honest prices.

North Carolina weather keeps HVAC systems busy year-round, and homes here depend on reliable electrical service for everything from daily living to powering modern technology. We handle AC breakdowns, heating installations, rewiring projects, and everything in between with the same attention to detail.

Ready for Service?

You shouldn't have to wonder if you're getting straight answers about your home's systems. Our approach is simple—we assess the situation, explain your options clearly, provide upfront pricing, and let you make informed decisions.

No games, no pressure, just skilled electrical and air conditioning technicians who respect your home and your time.

Call 919-887-8284 today.

Recent Jobs and Reviews in Cary, NC

Rated 5.0 out of 5 stars based on 67 customer reviews

Job Locations and Reviews

Responded to after-hours emergency call for AC not cooling lower level of home. Upon arrival, inspected Trane condenser unit and traced issue to condensate drain system. Found Safe-T-Switch safety device had triggered due to clogged condensate line, causing system shutdown to prevent water damage. Cleared blockage from PVC drain line, tested switch operation, and verified proper drainage flow. Restored system to normal operation with full cooling capacity confirmed before departure.
Responded to after-hours emergency call for AC not cooling lower level of home. Upon arrival, inspected Trane condenser unit and traced issue to condensate drain system. Found Safe-T-Switch safety device had triggered due to clogged condensate line, causing system shutdown to prevent water damage. Cleared blockage from PVC drain line, tested switch operation, and verified proper drainage flow. Restored system to normal operation with full cooling capacity confirmed before departure.
Hayes H.
Hayes H. Checked in
Responded to after-hours emergency call for AC not cooling lower level of home. Upon arrival, inspected Trane condenser unit and traced issue to condensate drain system. Found Safe-T-Switch safety device had triggered due to clogged condensate line, causing system shutdown to prevent water damage. Cleared blockage from PVC drain line, tested switch operation, and verified proper drainage flow. Restored system to normal operation with full cooling capacity confirmed before departure.
Cary, NC 27513
Responded to service call at 2018 residential property with multiple electrical issues. Investigated and resolved pantry light sensor malfunction that would not turn off. Diagnosed garage lighting circuit failure related to recently installed landscape lighting system and restored power to garage lights. Troubleshot and repaired several non-functioning outlets throughout the property, including critical pool pump outlet. Inspected electrical panel and verified proper connections at 240V receptacle. All circuits tested and confirmed operational upon completion.
Responded to service call at 2018 residential property with multiple electrical issues. Investigated and resolved pantry light sensor malfunction that would not turn off. Diagnosed garage lighting circuit failure related to recently installed landscape lighting system and restored power to garage lights. Troubleshot and repaired several non-functioning outlets throughout the property, including critical pool pump outlet. Inspected electrical panel and verified proper connections at 240V receptacle. All circuits tested and confirmed operational upon completion.
Charlie B.
Charlie B. Checked in
Responded to service call at 2018 residential property with multiple electrical issues. Investigated and resolved pantry light sensor malfunction that would not turn off. Diagnosed garage lighting circuit failure related to recently installed landscape lighting system and restored power to garage lights. Troubleshot and repaired several non-functioning outlets throughout the property, including critical pool pump outlet. Inspected electrical panel and verified proper connections at 240V receptacle. All circuits tested and confirmed operational upon completion.
Cary, NC 27519
Completed comprehensive preventive maintenance on two HVAC systems including 80-point inspections, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Replaced air filters on both units and performed complete safety inspections on all heating and cooling components. All systems tested and operating within manufacturer specifications upon completion.
Completed comprehensive preventive maintenance on two HVAC systems including 80-point inspections, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Replaced air filters on both units and performed complete safety inspections on all heating and cooling components. All systems tested and operating within manufacturer specifications upon completion.
Hayes H.
Hayes H. Checked in
Completed comprehensive preventive maintenance on two HVAC systems including 80-point inspections, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Replaced air filters on both units and performed complete safety inspections on all heating and cooling components. All systems tested and operating within manufacturer specifications upon completion.
Cary, NC 27511
Completed permit correction inspection for closet air handler following crawlspace encapsulation. Identified two code violations: inadequate fresh air makeup due to eliminated crawlspace ventilation source requiring combustion air calculations and approved intake installation, and insulation material in direct contact with B-vent requiring minimum 1-inch clearance per code. Documented violations with photographs for remediation planning.
Completed permit correction inspection for closet air handler following crawlspace encapsulation. Identified two code violations: inadequate fresh air makeup due to eliminated crawlspace ventilation source requiring combustion air calculations and approved intake installation, and insulation material in direct contact with B-vent requiring minimum 1-inch clearance per code. Documented violations with photographs for remediation planning.
Keith M.
Keith M. Checked in
Completed permit correction inspection for closet air handler following crawlspace encapsulation. Identified two code violations: inadequate fresh air makeup due to eliminated crawlspace ventilation source requiring combustion air calculations and approved intake installation, and insulation material in direct contact with B-vent requiring minimum 1-inch clearance per code. Documented violations with photographs for remediation planning.
Cary, NC 27513
Performed second opinion diagnostic on upstairs air handler unit with reported no cooling condition. Previous contractor diagnosed failed TXV requiring replacement. Inspected attic-mounted blue air handler system, confirmed 2024 equipment age, evaluated refrigerant circuit components and ductwork connections. Provided labor estimate for TXV replacement with customer supplying warranty part through original equipment manufacturer.
Performed second opinion diagnostic on upstairs air handler unit with reported no cooling condition. Previous contractor diagnosed failed TXV requiring replacement. Inspected attic-mounted blue air handler system, confirmed 2024 equipment age, evaluated refrigerant circuit components and ductwork connections. Provided labor estimate for TXV replacement with customer supplying warranty part through original equipment manufacturer.
Connor G.
Connor G. Checked in
Performed second opinion diagnostic on upstairs air handler unit with reported no cooling condition. Previous contractor diagnosed failed TXV requiring replacement. Inspected attic-mounted blue air handler system, confirmed 2024 equipment age, evaluated refrigerant circuit components and ductwork connections. Provided labor estimate for TXV replacement with customer supplying warranty part through original equipment manufacturer.
Cary, NC 27519
Conducted sales consultation for homeowner requesting mini split system installation for four seasons room addition. Evaluated existing HVAC infrastructure at property built in 1990, currently served by single outdoor condensing unit located on exterior brick wall with landscaped perimeter. Photographed installation site to assess mounting locations, electrical access points, and optimal placement for outdoor unit and indoor air handler, taking into consideration existing condenser placement, brick and vinyl siding construction, and available wall space for line set routing to four seasons room area.
Conducted sales consultation for homeowner requesting mini split system installation for four seasons room addition. Evaluated existing HVAC infrastructure at property built in 1990, currently served by single outdoor condensing unit located on exterior brick wall with landscaped perimeter. Photographed installation site to assess mounting locations, electrical access points, and optimal placement for outdoor unit and indoor air handler, taking into consideration existing condenser placement, brick and vinyl siding construction, and available wall space for line set routing to four seasons room area.
Joe B.
Joe B. Checked in
Conducted sales consultation for homeowner requesting mini split system installation for four seasons room addition. Evaluated existing HVAC infrastructure at property built in 1990, currently served by single outdoor condensing unit located on exterior brick wall with landscaped perimeter. Photographed installation site to assess mounting locations, electrical access points, and optimal placement for outdoor unit and indoor air handler, taking into consideration existing condenser placement, brick and vinyl siding construction, and available wall space for line set routing to four seasons room area.
Cary, NC 27513
Responded to no cooling complaint on 10-year-old system with suspected refrigerant leak. Accessed air handler unit located in crawl space and performed visual inspection of equipment and surrounding area. Documented condition of unit and crawl space access point with photographs for service records.
Responded to no cooling complaint on 10-year-old system with suspected refrigerant leak. Accessed air handler unit located in crawl space and performed visual inspection of equipment and surrounding area. Documented condition of unit and crawl space access point with photographs for service records.
Connor G.
Connor G. Checked in
Responded to no cooling complaint on 10-year-old system with suspected refrigerant leak. Accessed air handler unit located in crawl space and performed visual inspection of equipment and surrounding area. Documented condition of unit and crawl space access point with photographs for service records.
Cary, NC 27513
Performed comprehensive HVAC system tune-up and inspection on outdoor condensing unit. Conducted electrical diagnostics including capacitor testing, which measured 395 microfarads and verified within acceptable operating range. Completed full system evaluation with no issues identified; unit operating properly per manufacturer specifications.
Performed comprehensive HVAC system tune-up and inspection on outdoor condensing unit. Conducted electrical diagnostics including capacitor testing, which measured 395 microfarads and verified within acceptable operating range. Completed full system evaluation with no issues identified; unit operating properly per manufacturer specifications.
Connor G.
Connor G. Checked in
Performed comprehensive HVAC system tune-up and inspection on outdoor condensing unit. Conducted electrical diagnostics including capacitor testing, which measured 395 microfarads and verified within acceptable operating range. Completed full system evaluation with no issues identified; unit operating properly per manufacturer specifications.
Cary, NC 27513
Review
Connor connor was very polite and knowledgeable and honest, I was impressed at all. He knew, right off his fingers and finding things immediately. I feel comfortable with him and I recommend him
Lorraine - Cary, NC 27511
Responded to service call for HVAC system receiving no power to breaker as reported by homeowner's air conditioning contractor. Upon arrival, performed voltage testing at the exterior AC disconnect box and confirmed proper 24.73 volt reading at control circuit. Proceeded to main electrical panel and conducted comprehensive inspection of all breakers and connections. Tested HVAC breaker and verified proper power supply and connectivity. Identified that the issue was not originating from the electrical panel or breaker, as all components tested within normal operating parameters. Additionally inspected under-cabinet lighting circuit per homeowner's request regarding flickering fixture. Documented all findings with photos of disconnect box testing and main electrical panel condition for service records.
Responded to service call for HVAC system receiving no power to breaker as reported by homeowner's air conditioning contractor. Upon arrival, performed voltage testing at the exterior AC disconnect box and confirmed proper 24.73 volt reading at control circuit. Proceeded to main electrical panel and conducted comprehensive inspection of all breakers and connections. Tested HVAC breaker and verified proper power supply and connectivity. Identified that the issue was not originating from the electrical panel or breaker, as all components tested within normal operating parameters. Additionally inspected under-cabinet lighting circuit per homeowner's request regarding flickering fixture. Documented all findings with photos of disconnect box testing and main electrical panel condition for service records.
Charlie B.
Charlie B. Checked in
Responded to service call for HVAC system receiving no power to breaker as reported by homeowner's air conditioning contractor. Upon arrival, performed voltage testing at the exterior AC disconnect box and confirmed proper 24.73 volt reading at control circuit. Proceeded to main electrical panel and conducted comprehensive inspection of all breakers and connections. Tested HVAC breaker and verified proper power supply and connectivity. Identified that the issue was not originating from the electrical panel or breaker, as all components tested within normal operating parameters. Additionally inspected under-cabinet lighting circuit per homeowner's request regarding flickering fixture. Documented all findings with photos of disconnect box testing and main electrical panel condition for service records.
Cary, NC 27513
Responded to no cooling call on 10-year-old system. Upon arrival, found thermostat in off position and unit not operating. Accessed attic-mounted air handler and inspected equipment. Verified electrical connections, ductwork configuration, and overall system condition. Documented existing installation showing air handler positioned across joists with flexible ductwork connections and aging insulation material present throughout attic space.
Responded to no cooling call on 10-year-old system. Upon arrival, found thermostat in off position and unit not operating. Accessed attic-mounted air handler and inspected equipment. Verified electrical connections, ductwork configuration, and overall system condition. Documented existing installation showing air handler positioned across joists with flexible ductwork connections and aging insulation material present throughout attic space.
Connor G.
Connor G. Checked in
Responded to no cooling call on 10-year-old system. Upon arrival, found thermostat in off position and unit not operating. Accessed attic-mounted air handler and inspected equipment. Verified electrical connections, ductwork configuration, and overall system condition. Documented existing installation showing air handler positioned across joists with flexible ductwork connections and aging insulation material present throughout attic space.
Cary, NC 27511
Responded to power loss in living room of 1991 residential property. Upon arrival, met with tenants and inspected 200-amp main electrical panel. Homeowner had previously shut off breaker due to buzzing noise. Conducted thorough visual inspection of panel interior, documenting breaker conditions, bus bar connections, and wiring configuration. All circuit breakers were found in OFF position during inspection. Photographed panel components including main disconnect, brass bus bars, and multiple 15-amp branch circuit breakers with proper labeling. Observed organized wire management with bundled neutral conductors along panel edges and properly routed branch circuit wiring. Contacted homeowner to discuss findings and provide pricing options for necessary repairs, per instruction not to discuss technical details with tenants. Advised homeowner to verify power company had not reported any service issues or partial power loss to property before proceeding with repairs.
Responded to power loss in living room of 1991 residential property. Upon arrival, met with tenants and inspected 200-amp main electrical panel. Homeowner had previously shut off breaker due to buzzing noise. Conducted thorough visual inspection of panel interior, documenting breaker conditions, bus bar connections, and wiring configuration. All circuit breakers were found in OFF position during inspection. Photographed panel components including main disconnect, brass bus bars, and multiple 15-amp branch circuit breakers with proper labeling. Observed organized wire management with bundled neutral conductors along panel edges and properly routed branch circuit wiring. Contacted homeowner to discuss findings and provide pricing options for necessary repairs, per instruction not to discuss technical details with tenants. Advised homeowner to verify power company had not reported any service issues or partial power loss to property before proceeding with repairs.
Curtis E.
Curtis E. Checked in
Responded to power loss in living room of 1991 residential property. Upon arrival, met with tenants and inspected 200-amp main electrical panel. Homeowner had previously shut off breaker due to buzzing noise. Conducted thorough visual inspection of panel interior, documenting breaker conditions, bus bar connections, and wiring configuration. All circuit breakers were found in OFF position during inspection. Photographed panel components including main disconnect, brass bus bars, and multiple 15-amp branch circuit breakers with proper labeling. Observed organized wire management with bundled neutral conductors along panel edges and properly routed branch circuit wiring. Contacted homeowner to discuss findings and provide pricing options for necessary repairs, per instruction not to discuss technical details with tenants. Advised homeowner to verify power company had not reported any service issues or partial power loss to property before proceeding with repairs.
Cary, NC 27513
Completed annual 32-point electrical system evaluation on 2016 home. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers and main disconnect. Conducted GFCI outlet testing using calibrated digital tester, verifying proper ground fault protection and correct voltage readings of 123 VAC. Tested all arc fault circuit interrupters to ensure fire protection functionality. Addressed initial service call regarding smoke detector malfunction by replacing batteries in all smoke and CO2 detectors throughout the residence and performed operational testing to confirm proper alarm function. Replaced customer-supplied light bulbs in fixtures up to 12 feet and cleaned ceiling fans within accessible height range. All electrical systems tested and verified operating within normal parameters upon completion of maintenance visit.
Completed annual 32-point electrical system evaluation on 2016 home. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers and main disconnect. Conducted GFCI outlet testing using calibrated digital tester, verifying proper ground fault protection and correct voltage readings of 123 VAC. Tested all arc fault circuit interrupters to ensure fire protection functionality. Addressed initial service call regarding smoke detector malfunction by replacing batteries in all smoke and CO2 detectors throughout the residence and performed operational testing to confirm proper alarm function. Replaced customer-supplied light bulbs in fixtures up to 12 feet and cleaned ceiling fans within accessible height range. All electrical systems tested and verified operating within normal parameters upon completion of maintenance visit.
Isaac W.
Isaac W. Checked in
Completed annual 32-point electrical system evaluation on 2016 home. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers and main disconnect. Conducted GFCI outlet testing using calibrated digital tester, verifying proper ground fault protection and correct voltage readings of 123 VAC. Tested all arc fault circuit interrupters to ensure fire protection functionality. Addressed initial service call regarding smoke detector malfunction by replacing batteries in all smoke and CO2 detectors throughout the residence and performed operational testing to confirm proper alarm function. Replaced customer-supplied light bulbs in fixtures up to 12 feet and cleaned ceiling fans within accessible height range. All electrical systems tested and verified operating within normal parameters upon completion of maintenance visit.
Cary, NC 27519
Responded to no cooling complaint on lower central air conditioning unit tripping breaker after approximately 30 minutes of operation. Performed diagnostic testing using digital multimeter on control board and electrical components to identify circuit issues. Measured amperage draw on system components using clamp meter at compressor and blower motor connections to isolate cause of breaker trip condition.
Responded to no cooling complaint on lower central air conditioning unit tripping breaker after approximately 30 minutes of operation. Performed diagnostic testing using digital multimeter on control board and electrical components to identify circuit issues. Measured amperage draw on system components using clamp meter at compressor and blower motor connections to isolate cause of breaker trip condition.
Aaron P.
Aaron P. Checked in
Responded to no cooling complaint on lower central air conditioning unit tripping breaker after approximately 30 minutes of operation. Performed diagnostic testing using digital multimeter on control board and electrical components to identify circuit issues. Measured amperage draw on system components using clamp meter at compressor and blower motor connections to isolate cause of breaker trip condition.
Cary, NC 27518
Responded to no cooling complaint on recall visit for intermittent thermostat failure. Upon arrival, confirmed thermostat display was blank and system was not operating. Inspected thermostat wiring and connections at wall location, finding loose wire terminations at the thermostat base that were causing intermittent power loss. Installed customer-provided replacement thermostat, properly terminated all low-voltage wiring to ensure secure connections, and verified proper system operation. Tested heating and cooling modes to confirm thermostat communication with HVAC equipment, with all functions operating normally upon departure.
Responded to no cooling complaint on recall visit for intermittent thermostat failure. Upon arrival, confirmed thermostat display was blank and system was not operating. Inspected thermostat wiring and connections at wall location, finding loose wire terminations at the thermostat base that were causing intermittent power loss. Installed customer-provided replacement thermostat, properly terminated all low-voltage wiring to ensure secure connections, and verified proper system operation. Tested heating and cooling modes to confirm thermostat communication with HVAC equipment, with all functions operating normally upon departure.
Keith M.
Keith M. Checked in
Responded to no cooling complaint on recall visit for intermittent thermostat failure. Upon arrival, confirmed thermostat display was blank and system was not operating. Inspected thermostat wiring and connections at wall location, finding loose wire terminations at the thermostat base that were causing intermittent power loss. Installed customer-provided replacement thermostat, properly terminated all low-voltage wiring to ensure secure connections, and verified proper system operation. Tested heating and cooling modes to confirm thermostat communication with HVAC equipment, with all functions operating normally upon departure.
Cary, NC 27513
Responded to service call for flickering bathroom light and outlet replacement request in 1987-built residence. Inspected bathroom lighting circuit and switch configuration, identifying potential loose connection or faulty switch causing intermittent operation. Evaluated multiple outlet locations throughout the home for replacement, documenting existing switch plates and electrical fixtures requiring upgrade to meet current safety standards and customer preferences.
Responded to service call for flickering bathroom light and outlet replacement request in 1987-built residence. Inspected bathroom lighting circuit and switch configuration, identifying potential loose connection or faulty switch causing intermittent operation. Evaluated multiple outlet locations throughout the home for replacement, documenting existing switch plates and electrical fixtures requiring upgrade to meet current safety standards and customer preferences.
Curtis E.
Curtis E. Checked in
Responded to service call for flickering bathroom light and outlet replacement request in 1987-built residence. Inspected bathroom lighting circuit and switch configuration, identifying potential loose connection or faulty switch causing intermittent operation. Evaluated multiple outlet locations throughout the home for replacement, documenting existing switch plates and electrical fixtures requiring upgrade to meet current safety standards and customer preferences.
Cary, NC 27513
Responded to no cooling complaint on upstairs system in a two-system residence with 9-year-old equipment. Upon arrival, confirmed thermostat was calling for cooling with setpoint at 74°F while space temperature had risen to 77°F. Air handler was operational with blower running, but supply air was not adequately cooled.

Performed diagnostic testing of the system and measured supply air temperature at 62.8°F at the ductwork in the attic space, indicating insufficient cooling capacity. Conducted refrigerant charge analysis using digital gauges, which revealed a low superheat reading of 0.22°F, confirming a refrigerant overcharge condition or possible restriction in the system. The abnormally low superheat suggests liquid refrigerant was reaching the compressor, creating potential for compressor damage if left unaddressed.

System restored to proper cooling operation with appropriate refrigerant charge levels verified and airflow confirmed adequate throughout the conditioned space.
Responded to no cooling complaint on upstairs system in a two-system residence with 9-year-old equipment. Upon arrival, confirmed thermostat was calling for cooling with setpoint at 74°F while space temperature had risen to 77°F. Air handler was operational with blower running, but supply air was not adequately cooled.

Performed diagnostic testing of the system and measured supply air temperature at 62.8°F at the ductwork in the attic space, indicating insufficient cooling capacity. Conducted refrigerant charge analysis using digital gauges, which revealed a low superheat reading of 0.22°F, confirming a refrigerant overcharge condition or possible restriction in the system. The abnormally low superheat suggests liquid refrigerant was reaching the compressor, creating potential for compressor damage if left unaddressed.

System restored to proper cooling operation with appropriate refrigerant charge levels verified and airflow confirmed adequate throughout the conditioned space.
Thomas M.
Thomas M. Checked in
Responded to no cooling complaint on upstairs system in a two-system residence with 9-year-old equipment. Upon arrival, confirmed thermostat was calling for cooling with setpoint at 74°F while space temperature had risen to 77°F. Air handler was operational with blower running, but supply air was not adequately cooled. Performed diagnostic testing of the system and measured supply air temperature at 62.8°F at the ductwork in the attic space, indicating insufficient cooling capacity. Conducted refrigerant charge analysis using digital gauges, which revealed a low superheat reading of 0.22°F, confirming a refrigerant overcharge condition or possible restriction in the system. The abnormally low superheat suggests liquid refrigerant was reaching the compressor, creating potential for compressor damage if left unaddressed. System restored to proper cooling operation with appropriate refrigerant charge levels verified and airflow confirmed adequate throughout the conditioned space.
Cary, NC 27518
Responded to no cooling complaint on upstairs system. Upon arrival, found 15-year-old air conditioning unit blowing warm air. Performed diagnostic inspection of outdoor condensing unit and indoor evaporator coil assembly. Identified failed dual run capacitor preventing compressor from operating. Capacitor tested below acceptable microfarad range with no voltage output to compressor circuit. Replaced defective capacitor with properly rated OEM replacement. Verified all electrical connections secure and proper wire routing. Tested system operation and confirmed compressor engaging, refrigerant pressures within normal range, and cold air delivery restored to upstairs zone. System operating normally at time of departure.
Responded to no cooling complaint on upstairs system. Upon arrival, found 15-year-old air conditioning unit blowing warm air. Performed diagnostic inspection of outdoor condensing unit and indoor evaporator coil assembly. Identified failed dual run capacitor preventing compressor from operating. Capacitor tested below acceptable microfarad range with no voltage output to compressor circuit. Replaced defective capacitor with properly rated OEM replacement. Verified all electrical connections secure and proper wire routing. Tested system operation and confirmed compressor engaging, refrigerant pressures within normal range, and cold air delivery restored to upstairs zone. System operating normally at time of departure.
Connor G.
Connor G. Checked in
Responded to no cooling complaint on upstairs system. Upon arrival, found 15-year-old air conditioning unit blowing warm air. Performed diagnostic inspection of outdoor condensing unit and indoor evaporator coil assembly. Identified failed dual run capacitor preventing compressor from operating. Capacitor tested below acceptable microfarad range with no voltage output to compressor circuit. Replaced defective capacitor with properly rated OEM replacement. Verified all electrical connections secure and proper wire routing. Tested system operation and confirmed compressor engaging, refrigerant pressures within normal range, and cold air delivery restored to upstairs zone. System operating normally at time of departure.
Cary, NC 27519
Responded to service call for two non-functioning floodlights serving pool and back porch areas. Upon arrival, opened main electrical panel to inspect circuit breakers and traced affected circuits. Used voltage testing equipment to diagnose power delivery issues to the outdoor lighting circuits. Identified tripped breakers and verified proper circuit operation after reset, restoring power to both floodlight fixtures.
Responded to service call for two non-functioning floodlights serving pool and back porch areas. Upon arrival, opened main electrical panel to inspect circuit breakers and traced affected circuits. Used voltage testing equipment to diagnose power delivery issues to the outdoor lighting circuits. Identified tripped breakers and verified proper circuit operation after reset, restoring power to both floodlight fixtures.
Charlie B.
Charlie B. Checked in
Responded to service call for two non-functioning floodlights serving pool and back porch areas. Upon arrival, opened main electrical panel to inspect circuit breakers and traced affected circuits. Used voltage testing equipment to diagnose power delivery issues to the outdoor lighting circuits. Identified tripped breakers and verified proper circuit operation after reset, restoring power to both floodlight fixtures.
Cary, NC 27519
Installed dedicated 240-volt circuit adjacent to electrical panel as requested. Verified proper voltage output of 122.3V at the newly installed receptacle using digital multimeter, confirming successful installation and safe operation of the circuit.
Installed dedicated 240-volt circuit adjacent to electrical panel as requested. Verified proper voltage output of 122.3V at the newly installed receptacle using digital multimeter, confirming successful installation and safe operation of the circuit.
Isaac W.
Isaac W. Checked in
Installed dedicated 240-volt circuit adjacent to electrical panel as requested. Verified proper voltage output of 122.3V at the newly installed receptacle using digital multimeter, confirming successful installation and safe operation of the circuit.
Cary, NC 27518
Review
Conner was great. Explained everything to me and I did not feel like he was trying to up sell me!
Cecelia - Cary, NC 27513
Completed comprehensive HVAC tune-up on two 8-year-old units. Performed thorough inspection of both systems, including blower assemblies, electrical components, control boards, and wiring connections. Noted significant dust accumulation on blower wheel and internal surfaces; cleaned and serviced as needed. Inspected all circuit boards, capacitors, and electrical connections for proper operation. Discussed membership program options with customer as requested.
Completed comprehensive HVAC tune-up on two 8-year-old units. Performed thorough inspection of both systems, including blower assemblies, electrical components, control boards, and wiring connections. Noted significant dust accumulation on blower wheel and internal surfaces; cleaned and serviced as needed. Inspected all circuit boards, capacitors, and electrical connections for proper operation. Discussed membership program options with customer as requested.
Connor G.
Connor G. Checked in
Completed comprehensive HVAC tune-up on two 8-year-old units. Performed thorough inspection of both systems, including blower assemblies, electrical components, control boards, and wiring connections. Noted significant dust accumulation on blower wheel and internal surfaces; cleaned and serviced as needed. Inspected all circuit boards, capacitors, and electrical connections for proper operation. Discussed membership program options with customer as requested.
Cary, NC 27513
Responded to service call for garage refrigerator repeatedly tripping dedicated circuit breaker. Upon inspection, found brand new refrigerator installation causing nuisance tripping on existing breaker in electrical panel. Inspected panel connections, verified proper wire sizing and terminations, and confirmed breaker was functioning correctly but likely undersized for the new appliance's startup amperage draw. Recommended upgrading circuit breaker to appropriate amperage rating to accommodate the refrigerator's compressor inrush current and prevent future tripping issues.
Responded to service call for garage refrigerator repeatedly tripping dedicated circuit breaker. Upon inspection, found brand new refrigerator installation causing nuisance tripping on existing breaker in electrical panel. Inspected panel connections, verified proper wire sizing and terminations, and confirmed breaker was functioning correctly but likely undersized for the new appliance's startup amperage draw. Recommended upgrading circuit breaker to appropriate amperage rating to accommodate the refrigerator's compressor inrush current and prevent future tripping issues.
Bryant C.
Bryant C. Checked in
Responded to service call for garage refrigerator repeatedly tripping dedicated circuit breaker. Upon inspection, found brand new refrigerator installation causing nuisance tripping on existing breaker in electrical panel. Inspected panel connections, verified proper wire sizing and terminations, and confirmed breaker was functioning correctly but likely undersized for the new appliance's startup amperage draw. Recommended upgrading circuit breaker to appropriate amperage rating to accommodate the refrigerator's compressor inrush current and prevent future tripping issues.
Cary, NC 27511
Review
Keith was very professional and was very through doing his job.
Cindy - Cary, NC 27513
Responded to recall for intermittent thermostat operation following previous service visit. Performed comprehensive thermostat inspection and system diagnostics on R4A424LKA100 air conditioning unit (Serial: X212129316, May 2021 manufacture). Verified thermostat wiring connections, tested cycling operation, and confirmed proper communication between thermostat and outdoor unit. System operating within normal parameters at time of inspection with no faults detected.
Responded to recall for intermittent thermostat operation following previous service visit. Performed comprehensive thermostat inspection and system diagnostics on R4A424LKA100 air conditioning unit (Serial: X212129316, May 2021 manufacture). Verified thermostat wiring connections, tested cycling operation, and confirmed proper communication between thermostat and outdoor unit. System operating within normal parameters at time of inspection with no faults detected.
Keith M.
Keith M. Checked in
Responded to recall for intermittent thermostat operation following previous service visit. Performed comprehensive thermostat inspection and system diagnostics on R4A424LKA100 air conditioning unit (Serial: X212129316, May 2021 manufacture). Verified thermostat wiring connections, tested cycling operation, and confirmed proper communication between thermostat and outdoor unit. System operating within normal parameters at time of inspection with no faults detected.
Cary, NC 27513
Responded to no power condition in garage following tripped breaker from EV charging attempt. Tested GFCI outlet with Klein RT250 tester confirming proper grounding and circuit integrity after reset. Inspected electrical panel and verified dedicated tankless water heater circuit remained operational throughout service call, with all affected garage circuits restored to normal operation.
Responded to no power condition in garage following tripped breaker from EV charging attempt. Tested GFCI outlet with Klein RT250 tester confirming proper grounding and circuit integrity after reset. Inspected electrical panel and verified dedicated tankless water heater circuit remained operational throughout service call, with all affected garage circuits restored to normal operation.
Isaac W.
Isaac W. Checked in
Responded to no power condition in garage following tripped breaker from EV charging attempt. Tested GFCI outlet with Klein RT250 tester confirming proper grounding and circuit integrity after reset. Inspected electrical panel and verified dedicated tankless water heater circuit remained operational throughout service call, with all affected garage circuits restored to normal operation.
Cary, NC 27518
Cary, NC - Responded to service call regarding protruding kitchen outlet extending approximately one inch from wall surface. Upon arrival, found electrical receptacle improperly seated in junction box with surrounding drywall requiring adjustment. Repositioned outlet to sit flush with wall, secured device properly within electrical box, and verified stable installation and proper electrical function.
Curtis E.
Curtis E. Checked in
Responded to service call regarding protruding kitchen outlet extending approximately one inch from wall surface. Upon arrival, found electrical receptacle improperly seated in junction box with surrounding drywall requiring adjustment. Repositioned outlet to sit flush with wall, secured device properly within electrical box, and verified stable installation and proper electrical function.
Cary, NC 27519
Completed comprehensive electrical upgrade including installation of three dedicated circuits for microwave, cooktop, and garage door opener. Replaced up to 90 switches and outlets throughout residence with tamper-resistant, GFCI-protected devices featuring mechanical wrap terminations. Installed new dryer outlet and weather-resistant outdoor outlet covers. All work performed to code with permits coordinated through local inspection department. Testing confirmed proper voltage and ground fault protection on all circuits. Five-year warranty provided on all installations.
Completed comprehensive electrical upgrade including installation of three dedicated circuits for microwave, cooktop, and garage door opener. Replaced up to 90 switches and outlets throughout residence with tamper-resistant, GFCI-protected devices featuring mechanical wrap terminations. Installed new dryer outlet and weather-resistant outdoor outlet covers. All work performed to code with permits coordinated through local inspection department. Testing confirmed proper voltage and ground fault protection on all circuits. Five-year warranty provided on all installations.
Kenny L.
Kenny L. Checked in
Completed comprehensive electrical upgrade including installation of three dedicated circuits for microwave, cooktop, and garage door opener. Replaced up to 90 switches and outlets throughout residence with tamper-resistant, GFCI-protected devices featuring mechanical wrap terminations. Installed new dryer outlet and weather-resistant outdoor outlet covers. All work performed to code with permits coordinated through local inspection department. Testing confirmed proper voltage and ground fault protection on all circuits. Five-year warranty provided on all installations.
Cary, NC 27513
Review
Bryant, my technician did a great job and was considerate of my home and explained all work.
Joe Favila - Cary, NC 27511
Response from Dawson's Electric & Air:

Thank you, Joe! We appreciate you taking the time to share your experience. We're glad Bryant provided a great experience while preparing your shower exhaust fan installation quote for your Cary home. Treating our customers' homes with respect, explaining the recommended work clearly, and answering questions honestly are all important parts of the service we strive to provide from the very first visit. Thank you for considering Dawson's Electric & Air for your electrical project. We appreciate the opportunity to earn your trust and look forward to helping you with your shower fan installation and any future electrical needs in Cary and throughout the Raleigh area. 7/1/26 Thank you, Joe, for your 5-star rating! We appreciate you trusting Dawson's Electric & Air to help improve the brightness of the recessed can lights in your Cary home. We're glad Bryant was able to provide the quality service and expertise needed to get your lighting just right. Whether it's lighting upgrades, electrical troubleshooting, or repairs, our team is committed to delivering solutions you can count on. Thank you for choosing us for your electrical needs, we look forward to serving you again!

Review
Thomas did a great job. He was knowledgeable and friendly and worked efficiently.
Erin Mountain - Cary, NC 27513
Response from Dawson's Electric & Air:

Thank you, Erin, for your kind words! We're so glad to hear that Thomas provided knowledgeable, friendly, and efficient service. At Dawson's Electric & Air, we take pride in delivering professional electrical and HVAC services that homeowners throughout Raleigh, Fuquay-Varina, Holly Springs, Garner, and the surrounding areas can trust. We'll be sure to share your feedback with Thomas. Thank you for choosing Dawson's, and we look forward to helping with any future electrical or heating and cooling needs!

Review
We had an excellent experience with Curtis Edens from Dawson's Electric & Air. Our A/C units stopped working due to a damaged breaker caused by a loose electrical connection. Curtis quickly identified the root cause, explained the issue clearly, replaced the damaged breaker, repaired the affected wiring, and restored everything safely and efficiently. What really stood out was his thoroughness. He took the time to inspect several other electrical concerns throughout our home and identified loose backstabbed wiring connections and failing switches that could have caused future problems. He patiently explained what he found, answered all our questions, and provided practical recommendations to improve the safety and reliability of our electrical system. Curtis is knowledgeable, professional, honest, and detail-oriented. We never felt rushed or pressuredjust well-informed and confident that the work was done right. We highly recommend Dawson's Electric & Air, and will not hesitate to call them again for future electrical needs. We are grateful for the excellent service and the peace of mind that comes from knowing the work was done correctly and safely.
George M - Cary, NC 27519
Response from Dawson's Electric & Air:

Thank you, George, for such a detailed and thoughtful review! We’re honored that you trusted Dawson’s Electric & Air and Curtis to diagnose and repair the electrical issue that caused your air conditioning units to stop working. Electrical problems such as loose connections, damaged breakers, and failing wiring can create both safety concerns and unexpected HVAC system failures, so we’re glad we were able to identify the root cause, complete the necessary electrical repairs, and restore power safely. We believe homeowners deserve more than a quick fix, which is why our team takes the time to perform a thorough evaluation, explain our findings, and provide recommendations that help improve the long-term safety and reliability of their electrical systems. Your comments about Curtis's professionalism, attention to detail, and clear communication you received mean a great deal to us. At Dawson’s Electric & Air, our goal is to provide honest electrical service and help homeowners make informed decisions without pressure. Thank you again for your recommendation and for allowing us to serve your home. We look forward to helping with any future electrical, HVAC, or home safety needs. Your peace of mind truly is our priority!

Review
Isaac was exemplary in his work today will detailed explanations as well as answers to our questions during his review. Very pleased with everything
Rich - Cary, NC 27519
Review
Mr. D'Entremont was very knowledgeable and a true professional. He provided outstanding service and was very thorough.
T. D. - Cary, NC 27513
Review
Isaac was so thorough, competent and polite! A joy to turn to for help. Thank you Dawsons for another outstanding electrician!
CZiebis Peterson - Cary, NC 27519
Response from Dawson's Electric & Air:

Claudia, thank you for the kind review! We’re glad to hear you had another great experience with Dawson’s Electric & Air. Isaac takes a lot of pride in being thorough, competent, and polite, and we’re happy he was able to come out and diagnose the buzzing doorbell issue for you quickly and professionally. Doorbell transformer and wiring issues can be frustrating and sometimes hard to pinpoint, so we’re glad Isaac was able to identify the cause and help get things back to normal. We truly appreciate you trusting us with your home’s electrical service, and we’re always here whenever you need help again.

Review
We greatly appreciate the quick and competent response we received from Dawson's. We also appreciate that Hayes Hall explained the situation so quickly and thoroughly and even showed us pictures of what he was talking about and what he found. Thank you very much!
Merle Finch - Cary, NC 27518
Response from Dawson's Electric & Air:

Merle, thank you for your wonderful review! We’re glad Hayes was able to provide a quick response and get to the bottom of the issue with your air conditioning system. Taking the time to explain HVAC problems, review repair options, and provide photos of what we find is all part of delivering the peace of mind our customers deserve. We appreciate you trusting Dawson’s Electric & Air with your AC repair and electrical troubleshooting needs in Cary. Thank you for choosing our team, and please let us know if we can help with any future heating, cooling, or electrical services.

Review
Our technician, Bryant, was knowledgeable and friendly when making diagnoses of the electrical problems that we had. He was clear about pricing and the work that needed to be done. He completed the work quickly and made sure everything was working before he left.
Jake - Cary, NC 27513
Review
Shaya Silvers - Cary, NC 27519
Response from Dawson's Electric & Air:

Thank you, Shaya, for the 5-star review! We truly appreciate you trusting Dawson's Electric & Air with your home's electrical upgrades. It was our pleasure to install your dedicated office circuit, Ethernet connection, bathroom GFCI outlet, and whole-home surge protector. Our team is committed to providing safe, reliable electrical services that help protect your home and support your family's daily needs. Thank you for choosing Dawson's Electric & Air for your electrical installation and surge protection needs. We look forward to serving you again in the future!

Review
Outstanding service! Charlie Blanchard went above and beyond to help us when we lost power, which is an understatement for the amount of work he did to fix our issue. He volunteered his day off, a Saturday, to get everything restored as quickly as possible. He was professional and genuinely committed to helping his customers. We couldn't be more grateful and highly recommend him!
Abigail Knapp - Cary, NC 27519
Response from Dawson's Electric & Air:

Thank you, Abigail, for taking the time to share your experience and for the wonderful 5-star review! We're thrilled to hear that Charlie was able to help restore power to your home during such a stressful situation. At Dawson's Electric & Air, we understand how important it is to have a safe and reliable electrical system, and Charlie's dedication to providing exceptional electrical service truly reflects our commitment to our customers. Going above and beyond to solve electrical issues quickly and safely is what our team strives for every day, and we're proud to hear Charlie's professionalism, expertise, and willingness to help made such a positive impact. We'll be sure to share your kind words with him. Thank you for trusting Dawson's Electric & Air with your electrical repair needs and for recommending us to others. We're always here when you need a trusted electrician!

Review
Connor was terrific at explaining the problem with my AC unit. He walked me through what caused the problem and what he would do to correct it.
Bonnie - Cary, NC 27519
Review
Rob Wishart went above and beyond, great communication and great customer service!! Thank you Rob!!!
Jiffy - Cary, NC 27518
Review
Excellent work by Hayes with detailed explanation along with pics of the work performed
Rich - Cary, NC 27519
Review
Isaac is a tremendous employee of Dawson. Today, Issac was very capable, extremely friendly, smart, respectful, and exhibited a very, very positive image of Dawson. It was a pleasure to have this very capable young man as our Dawson representative
Paul - Cary, NC 27518
Review
Their service was done with integrity, quality and politeness. I will call them again for service I can trust.
Marice - Cary, NC 27513
Review
Great service
Leith - Cary, NC 27511
Review
Arron did and incredible job. Most appreciated
Bill - Cary, NC 27518
Review
He was very thorough and found the problem
Rochelle - Cary, NC 27513
Review
Professional
Linda - Cary, NC 27519
Review
Fantastic
Monica - Cary, NC 27511
Review
Jim Gangi came out and diagnosed the issues, conveyed his opinion and suggestions. No pressure and communicated his findings very well
John - Cary, NC 27519
Review
5-star experience! Easy to make an appointment, great communication, excellent work from knowledgeable, experienced, friendly electricians. Site cleanup was perfect. Will definitely hire Dawson’s Electric again! Thanks, Jonathan and Mason!
Mari - Cary, NC 27519
Review
Great and Friendly Service!
Praveen - Cary, NC 27519
Review
Jim was so helpful and proactive. He made sure that everything was cleaned. He came prepared with parts I didn’t have and he was absolutely pleasant to speak with! Ive always had awesome service with Dawson’s. I highly recommend them for any electrical work you need done.
Kylie - Cary, NC 27511
Review
Great service!
Cynthia - Cary, NC 27519
Review
Tim is top notch. He and his partner were efficient, thoughtful, and laid out multiple price options for our service needs. He generously threw in a couple additions at no cost. Very nice guy as well. Would highly recommend.
Alex G - Cary, NC 27511
Review
Jonathan Baker did an excellent job of explaining options for my electrical system. He worked quickly and efficiently and was patient in explaining how my new gear works. Much appreciated!
Carolyn - Cary, NC 27519
Review
Johnathan and Michael were very helpful
Laura - Cary, NC 27513
Review
Jim did a really great job for us! The recessed lights he wired up in the living room just sparkle and we could not be happier. He also did excellent work in our garage and made sure to replace as much drywall as possible to cut down on our repairs. We would hire him again!
Caroline - Cary, NC 27513