Expert Electrical & HVAC Services For Willow Spring, NC
We’ve been serving homeowners in Willow Spring, NC since 2005, bringing honest electrical and HVAC work to folks who deserve straightforward service they can count on. Over the years, we’ve helped thousands of families keep their homes comfortable and safe, handling everything from emergency AC repairs in the middle of summer to heating system replacements before winter sets in. When your air conditioner stops working or your furnace won’t fire up, you need a team that can diagnose the problem quickly and fix it right. That’s what we do. We also handle electrical repairs, panel upgrades, EV charger installations, and all the other services that keep your home running smoothly.
Our approach is simple: show up on time, explain what’s going on in plain language, give you honest pricing upfront, and complete the work with the kind of craftsmanship we’d want in our own homes. No gimmicks, no shortcuts—just quality work from people who take pride in what they do and care about the community we serve.
Five-star service isn’t something we just talk about—it’s something we deliver on every single job, and our reviews prove it. Over the years, we’ve earned hundreds of five-star ratings from customers right here in Willow Spring who’ve trusted us with their electrical and HVAC needs. Whether it’s an AC installation, a heating repair, or rewiring part of their home, people appreciate the way we handle their projects with care and respect. Don’t just take our word for it, though. Head over to our reviews page or check us out on Google to see what your neighbors are saying about working with our team. You’ll find honest feedback from real people who’ve experienced the quality and professionalism we bring to every call.
From the first phone call to the final walkthrough, we’re committed to earning those five stars. When you’re ready for electrical or HVAC service that’s done right, call us at 919-887-8284 to schedule your appointment. We’re looking forward to serving you!
Recent Jobs and Reviews in Willow Spring, NC
Our Local Reviews by City
- Angier, NC (28)
- Apex, NC (73)
- Benson, NC (1)
- Bunnlevel, NC (1)
- Cary, NC (62)
- Chapel Hill, NC (26)
- Clayton, NC (6)
- Coats, NC (1)
- Dunn, NC (1)
- Durham, NC (18)
- Fuquay-Varina, NC (213)
- Garner, NC (17)
- Godwin, NC (1)
- Holly Springs, NC (87)
- Knightdale, NC (1)
- Lillington, NC (21)
- Middle Creek, NC (3)
- Middle Creek Township, NC (1)
- Moncure, NC (1)
- Morrisville, NC (4)
- New Hill, NC (1)
- Panther Branch, NC (2)
- Pittsboro, NC (10)
- Pleasant Grove, NC (2)
- Raleigh, NC (98)
- Wake Forest, NC (8)
- Wendell, NC (3)
- Willow Spring, NC (4)
Job Locations and Reviews
Completed comprehensive heating and air maintenance on single HVAC unit, including full 80-point inspection, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Performed thorough safety inspections and electrical diagnostics on system components, verifying proper operation of blower motor assembly and control circuitry. All equipment tested and confirmed operating within manufacturer specifications.
Responded to no cooling condition on downstairs unit in two-system residence with 7-8 year old equipment. Performed diagnostic evaluation and found outdoor condenser coil heavily contaminated with debris restricting airflow. Thoroughly cleaned condenser coil using foaming coil cleaner and brush to restore proper heat transfer. Verified system operation with amperage readings showing 16.5A draw, indicating compressor running within normal parameters. Unit restored to proper cooling operation with adequate airflow through supply vents.
Responded to return visit for non-functioning GFCI outlet in garage that was previously installed. Upon arrival, verified that the GFCI receptacle was not resetting properly and the indicator light was not illuminating, which resulted in downstream outlets in the living room and front porch losing power. Performed diagnostic testing using Klein Tools RT250 GFCI outlet tester, which confirmed proper voltage reading of 123 VAC and correct wiring configuration. Inspected electrical panel and circuit breaker connections to verify proper power supply to the affected circuit. Tested GFCI protection functionality and confirmed outlet is now operating correctly with proper reset capability and indicator light function restored. All affected outlets in living room and front porch verified to have power restored and functioning normally.
Responded to no cooling call where Honeywell Home thermostat displayed "Reading Sensors" error message and "No Power to heat/cool system" warning. Upon inspection, verified thermostat was showing system offline status and measured supply air temperature at 53.5°F at ductwork, confirming lack of cooling operation. Diagnosed power supply issue preventing communication between thermostat and HVAC system, restored power to unit, and verified system returned to normal operation with proper thermostat communication established.
Responded to warranty service call for new upstairs HVAC unit not cooling with thermostat reading in the 80s. Inspected electrical control panel wiring connections and terminal strips, verified proper wire routing and connections throughout system. Examined attic installation including ductwork, insulation placement, and flexible ducting to identify potential cooling performance issues related to recent installation.
# HVAC Installation Completed Successfully installed a Friedrich air conditioning unit model WFPU175X363D with A2L refrigerant certification. The installation included proper mounting of the outdoor condenser unit, completion of all electrical connections with appropriate wire terminations, and secure placement of flexible conduit for power supply routing. All manufacturer specification labels and safety warnings were verified in place, including ARI certification documentation and hazard notifications for A2L refrigerant handling. The unit was tested and confirmed operational with digital display reading 38.6 degrees, indicating proper system function. All access panels were secured, and insulated refrigerant lines were properly installed and wrapped to manufacturer specifications.
Responded to service call for non-functioning doorbell systems at residential property built in 1999. Customer had recently relocated Nest doorbell from side entry door to front door, resulting in loss of functionality at new location. Additionally, conventional doorbell installed at previous Nest location on side entry was also inoperative. Inspected both electrical service panels (exterior meter/breaker panel and interior main distribution panel) to verify power supply and circuit integrity for doorbell transformer and associated low-voltage wiring. Documented existing electrical infrastructure including circuit breaker configurations and wiring connections to assess compatibility with doorbell system requirements and troubleshoot power delivery issues affecting both doorbell installations.
Completed comprehensive heating and air maintenance on two HVAC systems, performing 80-point inspections on both units. Cleaned outdoor condenser coils on heat pump and air conditioning unit, performed burner cleaning, verified and adjusted gas pressures to manufacturer specifications, and conducted thorough safety inspections on all components. All systems operating within normal parameters upon completion.
Responded to lightning strike damage affecting both HVAC systems with non-functioning thermostats. Upon inspection, found outdoor condensing unit with damaged electrical components including capacitor and contactor, along with heavily soiled evaporator coil restricting airflow and showing signs of corrosion at refrigerant line connections. Replaced failed electrical components damaged by power surge, cleaned evaporator coil assembly, and restored system operation to both units.
Responded to lightning strike damage at residential property built in 2002. Conducted comprehensive electrical system inspection to assess damage throughout home. Multiple systems were affected including stove/oven, HVAC units, telecommunications equipment, and GFCI outlets. Breakers were experiencing repeated tripping and improper operation. Performed thorough diagnostic testing of electrical circuits using circuit analyzer to identify compromised wiring and components. Inspection revealed significant damage to electrical conductors with evidence of electrical arcing, heat damage, and burned insulation on wiring connected to electrical panel. Documented severely damaged cable showing exposed conductors with charred insulation and thermal degradation at connection points. Tested GFCI outlets throughout residence to determine extent of surge damage. Evaluated main electrical panel components, relays, and associated control wiring for signs of lightning-induced failure. Photographed da
Jeff was friendly and pointed everything out before he did the work. He was very thorough and friendly.
I have used Jason with Dawson's Electric on two different times. He was always prompt and did great work!
Always showed up when called!
Speedy, professional and inexpensive