Trusted Local Heating, Cooling, & Electrical Services for Knightdale Homes

Knightdale residents deserve reliable air conditioning, heating, and electrical service from a company that knows the area. Dawson's Electric & Air is your local provider, serving Knightdale with expert AC repair, installation, maintenance, furnace service, and comprehensive electrical work.

We're located nearby and available 24/7 for emergencies.

Whether you need AC repair before summer heat hits, furnace service before winter, electrical upgrades, EV charger installation, or generator backup power, we're here for your Knightdale home with all your HVAC and electrical needs under one roof.

  • Licensed and insured technicians serving Knightdale
  • 24/7 emergency service availability
  • Same-day appointments available
  • Free estimates for all new installations

Call 919-887-8284 today to schedule a service or contact us online.

Knightdale HVAC & Electrical Services FAQs

High-Efficiency Air Conditioning & Heating Services

The high humidity and seasonal temperature swings in East Wake County put heavy demands on residential heat pumps and central cooling systems. We provide complete HVAC care to keep your indoor environment clean, balanced, and energy-efficient year-round.

Fast AC Repair & Emergency Cooling Diagnostics

A cooling failure during a East Wake summer isn't just uncomfortable—it requires immediate, expert attention. Because our technicians carry dual expertise in HVAC and electrical diagnostics, we quickly isolate the root cause of cooling issues, including:

  • Electrical Overloads & Tripped Breakers: Troubleshooting failing capacitors, burnt wiring, and short-cycling compressors before they cause panel damage.

  • Refrigerant Line Leaks: Precision leak detection, coil repairs, and eco-friendly refrigerant recharges.

  • Airflow Restrictions: Resolving frozen evaporator coils, blower motor failures, and restricted return air vents.

HVAC Replacements & Heat Pump Installation

Many homes built in Knightdale’s expansion during the late 2000s and early 2010s feature builder-grade systems that are now reaching the end of their 10–12 year operational lifespan. We perform detailed Load Calculations (Manual J) to ensure your replacement system matches your floor plan perfectly.

  • Authorized Installations: High-SEER2 central air conditioners, variable-speed heat pumps, and ductless mini-splits.

  • Ductwork & Airflow Balancing: Static pressure testing to eliminate hot spots in multi-story floor plans.

Proactive Seasonal HVAC Maintenance

Prevent costly mid-season breakdowns with bi-annual preventive maintenance. Our seasonal tune-ups include chemical coil cleaning, electrical terminal tightening, condensate drain flushing, and thermostat recalibration.

Electrical Services We Offer in Knightdale

Holding an Electrical License, Dawson’s licensed electricians handle everything from routine outlet repairs to high-capacity panel overhauls for residential and commercial properties across Knightdale.

Electrical Panel Upgrades & Heavy-Ups

As Knightdale families add EV chargers, finished basements, and modern appliances, older 100-amp and 150-amp electrical panels can become overloaded.

  • 200-Amp & 400-Amp Upgrades: Safely increase your home's amperage capacity to support modern high-draw electrical equipment.

  • Utility Coordination: We work directly with Duke Energy Progress and manage all trade permits required by Town of Knightdale Development Services and the Wake County Permit Portal.

Home EV Charger Installation (Level 2)

Charge your electric vehicle up to 7x faster than a standard wall outlet. We install hardwired and outlet-based Level 2 charging stations (Tesla Wall Connector, ChargePoint, JuiceBox) with full panel load management.

Whole-Home Standby Generators & Surge Protection

Protect your property from sudden outages and grid fluctuations caused by severe weather along the Neuse River basin.

  • Automatic Standby Generators: Turnkey installation of Generac and Kohler generators with automatic transfer switches.

  • Whole-Home Surge Protectors: Main-panel surge suppression to shield delicate microelectronics, HVAC control boards, and smart appliances from power spikes.

Ready to Schedule AC, Heating, or Electrical Service in Knightdale?

Your AC, heating, and electrical needs matter. Dawson's Electric & Air is your trusted Knightdale service provider for all your home comfort and electrical needs. Call us today for fast, reliable service from experienced technicians.

  • Free estimates for new installations
  • Same-day appointments available
  • 24/7 emergency service for AC, heating & electrical
  • Licensed and insured
  • HVAC and electrical expertise under one roof

Call 919-887-8284 or schedule service online.

Recent Jobs and Reviews in Knightdale, NC

Rated 5.0 out of 5 stars based on 2 customer reviews

Job Locations and Reviews

Completed comprehensive spring preventive maintenance on HVAC system including full 80-point inspection of all units. Performed electrical diagnostics with capacitor testing showing 46.4 microfarads and verified amperage draw at 10.18 amps with proper voltage readings. Cleaned outdoor coils, performed burner cleaning, adjusted gas pressures to manufacturer specifications, and completed all required safety inspections.
Completed comprehensive spring preventive maintenance on HVAC system including full 80-point inspection of all units. Performed electrical diagnostics with capacitor testing showing 46.4 microfarads and verified amperage draw at 10.18 amps with proper voltage readings. Cleaned outdoor coils, performed burner cleaning, adjusted gas pressures to manufacturer specifications, and completed all required safety inspections.
Hayes H.
Hayes H. Checked in
Completed comprehensive spring preventive maintenance on HVAC system including full 80-point inspection of all units. Performed electrical diagnostics with capacitor testing showing 46.4 microfarads and verified amperage draw at 10.18 amps with proper voltage readings. Cleaned outdoor coils, performed burner cleaning, adjusted gas pressures to manufacturer specifications, and completed all required safety inspections.
Knightdale, NC 27545
Review
The technician was very good and solved our problem quickly.
Clifford - Knightdale, NC 27545
Responded to non-functioning switches in garage of 2018 home. Inspected electrical panel and identified tripped GFCI circuit affecting two garage switches. Reset GFCI receptacle, verified proper circuit protection at main panel, and tested both switches to confirm restored functionality and proper grounding.
Responded to non-functioning switches in garage of 2018 home. Inspected electrical panel and identified tripped GFCI circuit affecting two garage switches. Reset GFCI receptacle, verified proper circuit protection at main panel, and tested both switches to confirm restored functionality and proper grounding.
Bryant C.
Bryant C. Checked in
Responded to non-functioning switches in garage of 2018 home. Inspected electrical panel and identified tripped GFCI circuit affecting two garage switches. Reset GFCI receptacle, verified proper circuit protection at main panel, and tested both switches to confirm restored functionality and proper grounding.
Knightdale, NC 27545
Responded to no cooling complaint affecting rear portion of residence. Found inadequate airflow to back zones while front and upstairs areas maintained proper air delivery. Performed static pressure diagnostics on air handler unit using digital manometer, recording 0.74" measurement. Inspected ductwork system and air handler located in basement area. Identified zoning system issue affecting one of three thermostats controlling the property. Verified proper operation of equipment and supply duct connections at main unit.
Responded to no cooling complaint affecting rear portion of residence. Found inadequate airflow to back zones while front and upstairs areas maintained proper air delivery. Performed static pressure diagnostics on air handler unit using digital manometer, recording 0.74" measurement. Inspected ductwork system and air handler located in basement area. Identified zoning system issue affecting one of three thermostats controlling the property. Verified proper operation of equipment and supply duct connections at main unit.
Thomas M.
Thomas M. Checked in
Responded to no cooling complaint affecting rear portion of residence. Found inadequate airflow to back zones while front and upstairs areas maintained proper air delivery. Performed static pressure diagnostics on air handler unit using digital manometer, recording 0.74" measurement. Inspected ductwork system and air handler located in basement area. Identified zoning system issue affecting one of three thermostats controlling the property. Verified proper operation of equipment and supply duct connections at main unit.
Knightdale, NC 27545
Responded to no cooling call on 11-year-old residential air conditioning system. Upon arrival, inspected indoor evaporator coil assembly located in attic space and found extensive rust and corrosion on refrigerant lines and coil framework, indicating prolonged moisture exposure and system deterioration. Observed compromised refrigerant line integrity with heavy oxidation on copper tubing and mounting brackets. System components showed significant age-related wear consistent with equipment nearing end of service life. Documented conditions with photos showing corroded coil assembly, deteriorated insulation, and moisture damage throughout attic installation area for customer review and replacement recommendations.
Responded to no cooling call on 11-year-old residential air conditioning system. Upon arrival, inspected indoor evaporator coil assembly located in attic space and found extensive rust and corrosion on refrigerant lines and coil framework, indicating prolonged moisture exposure and system deterioration. Observed compromised refrigerant line integrity with heavy oxidation on copper tubing and mounting brackets. System components showed significant age-related wear consistent with equipment nearing end of service life. Documented conditions with photos showing corroded coil assembly, deteriorated insulation, and moisture damage throughout attic installation area for customer review and replacement recommendations.
Thomas M.
Thomas M. Checked in
Responded to no cooling call on 11-year-old residential air conditioning system. Upon arrival, inspected indoor evaporator coil assembly located in attic space and found extensive rust and corrosion on refrigerant lines and coil framework, indicating prolonged moisture exposure and system deterioration. Observed compromised refrigerant line integrity with heavy oxidation on copper tubing and mounting brackets. System components showed significant age-related wear consistent with equipment nearing end of service life. Documented conditions with photos showing corroded coil assembly, deteriorated insulation, and moisture damage throughout attic installation area for customer review and replacement recommendations.
Knightdale, NC 27545
Knightdale, NC - Replaced malfunctioning exterior motion sensor floodlight with integrated security camera at 12-foot mounting height on corner of home exterior. Removed previously installed non-functional fixture and installed new white dual-LED floodlight camera unit on existing bracket mounted to horizontal lap siding, verifying proper operation of motion sensor and camera functions upon completion.
Isaac W.
Isaac W. Checked in
Replaced malfunctioning exterior motion sensor floodlight with integrated security camera at 12-foot mounting height on corner of home exterior. Removed previously installed non-functional fixture and installed new white dual-LED floodlight camera unit on existing bracket mounted to horizontal lap siding, verifying proper operation of motion sensor and camera functions upon completion.
Knightdale, NC 27545
Replaced failed evaporator coil in attic air handler under Peace of Mind agreement. Two technicians completed the installation of new Mitsubishi coil assembly, reconnected all electrical wiring and refrigerant lines, and verified proper system operation. Unit tested successfully with all controls functioning as designed.
Replaced failed evaporator coil in attic air handler under Peace of Mind agreement. Two technicians completed the installation of new Mitsubishi coil assembly, reconnected all electrical wiring and refrigerant lines, and verified proper system operation. Unit tested successfully with all controls functioning as designed.
Ethan N.
Ethan N. Checked in
Replaced failed evaporator coil in attic air handler under Peace of Mind agreement. Two technicians completed the installation of new Mitsubishi coil assembly, reconnected all electrical wiring and refrigerant lines, and verified proper system operation. Unit tested successfully with all controls functioning as designed.
Knightdale, NC 27545
Completed HVAC system installation including gas line connections with shut-off valves and integrated electronic control unit mounted in utility space. Established electrical service by connecting new circuit breakers in main panel to support system operation, with all connections tested and verified operational.
Completed HVAC system installation including gas line connections with shut-off valves and integrated electronic control unit mounted in utility space. Established electrical service by connecting new circuit breakers in main panel to support system operation, with all connections tested and verified operational.
Santos C.
Santos C. Checked in
Completed HVAC system installation including gas line connections with shut-off valves and integrated electronic control unit mounted in utility space. Established electrical service by connecting new circuit breakers in main panel to support system operation, with all connections tested and verified operational.
Knightdale, NC 27545
Completed comprehensive heating and air maintenance on single-unit system including 80-point inspection, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Verified all electrical connections and high-voltage components within cabinet are secure and functioning properly. Inspected Safe-T-Switch condensate overflow safety device and confirmed proper operation with no active drainage issues or blockages present.
Completed comprehensive heating and air maintenance on single-unit system including 80-point inspection, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Verified all electrical connections and high-voltage components within cabinet are secure and functioning properly. Inspected Safe-T-Switch condensate overflow safety device and confirmed proper operation with no active drainage issues or blockages present.
Thomas M.
Thomas M. Checked in
Completed comprehensive heating and air maintenance on single-unit system including 80-point inspection, outdoor coil cleaning, burner cleaning, and gas pressure adjustments. Verified all electrical connections and high-voltage components within cabinet are secure and functioning properly. Inspected Safe-T-Switch condensate overflow safety device and confirmed proper operation with no active drainage issues or blockages present.
Knightdale, NC 27545
Responded to no cooling call on 7-year-old system unable to maintain temperature below 76 degrees. Upon arrival, performed diagnostic testing using clamp meter to measure electrical draw and checked capacitor operation. Found failed run capacitor causing compressor to draw improper amperage. Replaced defective SUREPHON5 capacitor with manufacturer-specified unit. Verified proper electrical values, confirmed compressor operation, and tested system cooling performance. Unit now operating within normal parameters and achieving set temperature. Also referenced zone panel wiring diagram for TrueZONE H2432 conventional system to verify proper damper and thermostat connections during troubleshooting process.
Responded to no cooling call on 7-year-old system unable to maintain temperature below 76 degrees. Upon arrival, performed diagnostic testing using clamp meter to measure electrical draw and checked capacitor operation. Found failed run capacitor causing compressor to draw improper amperage. Replaced defective SUREPHON5 capacitor with manufacturer-specified unit. Verified proper electrical values, confirmed compressor operation, and tested system cooling performance. Unit now operating within normal parameters and achieving set temperature. Also referenced zone panel wiring diagram for TrueZONE H2432 conventional system to verify proper damper and thermostat connections during troubleshooting process.
Aaron P.
Aaron P. Checked in
Responded to no cooling call on 7-year-old system unable to maintain temperature below 76 degrees. Upon arrival, performed diagnostic testing using clamp meter to measure electrical draw and checked capacitor operation. Found failed run capacitor causing compressor to draw improper amperage. Replaced defective SUREPHON5 capacitor with manufacturer-specified unit. Verified proper electrical values, confirmed compressor operation, and tested system cooling performance. Unit now operating within normal parameters and achieving set temperature. Also referenced zone panel wiring diagram for TrueZONE H2432 conventional system to verify proper damper and thermostat connections during troubleshooting process.
Knightdale, NC 27545
Conducted sales consultation for complete HVAC system replacement on existing 2016 equipment. Evaluated current single-zone system with Honeywell zone control panel installed in attic space, assessed exterior condensing unit and associated line sets with weatherproof disconnect, and documented existing installation configuration. Provided replacement options for both furnace and air conditioning equipment to homeowner.
Conducted sales consultation for complete HVAC system replacement on existing 2016 equipment. Evaluated current single-zone system with Honeywell zone control panel installed in attic space, assessed exterior condensing unit and associated line sets with weatherproof disconnect, and documented existing installation configuration. Provided replacement options for both furnace and air conditioning equipment to homeowner.
Joe B.
Joe B. Checked in
Conducted sales consultation for complete HVAC system replacement on existing 2016 equipment. Evaluated current single-zone system with Honeywell zone control panel installed in attic space, assessed exterior condensing unit and associated line sets with weatherproof disconnect, and documented existing installation configuration. Provided replacement options for both furnace and air conditioning equipment to homeowner.
Knightdale, NC 27545
Responded to no-cooling call with both upstairs and downstairs thermostats displaying blank screens. Upon arrival, confirmed total loss of power to HVAC system despite homeowner's attempts to reset breakers. Conducted systematic diagnostic of 2016 unit and discovered complete electrical failure at furnace. Inspection revealed oil staining on furnace cabinet indicating potential transformer failure or electrical component breakdown. Additionally noted outdoor coil exhibited significant contamination with dirt and debris buildup restricting airflow through condenser fins. Documented conditions with photographs showing oil leakage patterns and dirty coil requiring cleaning for optimal system performance once power issue resolved.
Responded to no-cooling call with both upstairs and downstairs thermostats displaying blank screens. Upon arrival, confirmed total loss of power to HVAC system despite homeowner's attempts to reset breakers. Conducted systematic diagnostic of 2016 unit and discovered complete electrical failure at furnace. Inspection revealed oil staining on furnace cabinet indicating potential transformer failure or electrical component breakdown. Additionally noted outdoor coil exhibited significant contamination with dirt and debris buildup restricting airflow through condenser fins. Documented conditions with photographs showing oil leakage patterns and dirty coil requiring cleaning for optimal system performance once power issue resolved.
Aaron P.
Aaron P. Checked in
Responded to no-cooling call with both upstairs and downstairs thermostats displaying blank screens. Upon arrival, confirmed total loss of power to HVAC system despite homeowner's attempts to reset breakers. Conducted systematic diagnostic of 2016 unit and discovered complete electrical failure at furnace. Inspection revealed oil staining on furnace cabinet indicating potential transformer failure or electrical component breakdown. Additionally noted outdoor coil exhibited significant contamination with dirt and debris buildup restricting airflow through condenser fins. Documented conditions with photographs showing oil leakage patterns and dirty coil requiring cleaning for optimal system performance once power issue resolved.
Knightdale, NC 27545
Completed comprehensive heating and air maintenance on 2017 HVAC system including full 80-point inspection on all units. Performed outdoor coil cleaning, burner cleaning, and verified gas pressures with adjustments as needed. Measured differential pressure at 0.30 inches of water column, inspected refrigerant lines showing proper operation with normal frost accumulation, and conducted thorough safety inspection of electrical components and control cabinet wiring.
Completed comprehensive heating and air maintenance on 2017 HVAC system including full 80-point inspection on all units. Performed outdoor coil cleaning, burner cleaning, and verified gas pressures with adjustments as needed. Measured differential pressure at 0.30 inches of water column, inspected refrigerant lines showing proper operation with normal frost accumulation, and conducted thorough safety inspection of electrical components and control cabinet wiring.
Aaron P.
Aaron P. Checked in
Completed comprehensive heating and air maintenance on 2017 HVAC system including full 80-point inspection on all units. Performed outdoor coil cleaning, burner cleaning, and verified gas pressures with adjustments as needed. Measured differential pressure at 0.30 inches of water column, inspected refrigerant lines showing proper operation with normal frost accumulation, and conducted thorough safety inspection of electrical components and control cabinet wiring.
Knightdale, NC 27545
Responded to scheduled appointment for 16-year-old HVAC system with failed compressor. Assessed existing equipment located in crawl space, including air handler, condensate pump, and associated ductwork and refrigerant lines. Documented current system configuration with photographs showing aged unit with deteriorated components, existing flexible ductwork, copper line sets, electrical connections, and crawl space conditions including vapor barrier and concrete foundation. Provided customer with replacement options and recommendations for complete system replacement due to age of equipment and compressor failure.
Responded to scheduled appointment for 16-year-old HVAC system with failed compressor. Assessed existing equipment located in crawl space, including air handler, condensate pump, and associated ductwork and refrigerant lines. Documented current system configuration with photographs showing aged unit with deteriorated components, existing flexible ductwork, copper line sets, electrical connections, and crawl space conditions including vapor barrier and concrete foundation. Provided customer with replacement options and recommendations for complete system replacement due to age of equipment and compressor failure.
Everett C.
Everett C. Checked in
Responded to scheduled appointment for 16-year-old HVAC system with failed compressor. Assessed existing equipment located in crawl space, including air handler, condensate pump, and associated ductwork and refrigerant lines. Documented current system configuration with photographs showing aged unit with deteriorated components, existing flexible ductwork, copper line sets, electrical connections, and crawl space conditions including vapor barrier and concrete foundation. Provided customer with replacement options and recommendations for complete system replacement due to age of equipment and compressor failure.
Knightdale, NC 27545
Responded to no cooling complaint on 7-year-old system. Upon inspection, discovered significant debris and nest material obstructing the air handler and return air pathway. Removed obstruction, cleaned affected components, and verified proper airflow restoration. System tested and confirmed delivering proper cooling operation upon departure.
Responded to no cooling complaint on 7-year-old system. Upon inspection, discovered significant debris and nest material obstructing the air handler and return air pathway. Removed obstruction, cleaned affected components, and verified proper airflow restoration. System tested and confirmed delivering proper cooling operation upon departure.
Connor G.
Connor G. Checked in
Responded to no cooling complaint on 7-year-old system. Upon inspection, discovered significant debris and nest material obstructing the air handler and return air pathway. Removed obstruction, cleaned affected components, and verified proper airflow restoration. System tested and confirmed delivering proper cooling operation upon departure.
Knightdale, NC 27545
Knightdale, NC - Installed UV light system inside upstairs air handler to mitigate microbial growth. Replaced failing transformer in upstairs air handler that was producing loud buzzing noise and showing signs of electrical deterioration. All electrical connections verified and system tested for proper operation.
Thomas M.
Thomas M. Checked in
Installed UV light system inside upstairs air handler to mitigate microbial growth. Replaced failing transformer in upstairs air handler that was producing loud buzzing noise and showing signs of electrical deterioration. All electrical connections verified and system tested for proper operation.
Knightdale, NC 27545
Completed annual 32-point electrical system evaluation on 2017 residential property. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers in the Eaton panel. Conducted GFCI/shock protection outlet and breaker testing to verify proper ground fault protection functionality. Tested all arc fault circuit interrupters to ensure fire protection systems were operating within specifications. Performed smoke and carbon monoxide detector maintenance including battery replacement and functional testing of ceiling-mounted units throughout the home.
Completed annual 32-point electrical system evaluation on 2017 residential property. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers in the Eaton panel. Conducted GFCI/shock protection outlet and breaker testing to verify proper ground fault protection functionality. Tested all arc fault circuit interrupters to ensure fire protection systems were operating within specifications. Performed smoke and carbon monoxide detector maintenance including battery replacement and functional testing of ceiling-mounted units throughout the home.
Bryant C.
Bryant C. Checked in
Completed annual 32-point electrical system evaluation on 2017 residential property. Performed comprehensive electrical panel maintenance including torque verification and connection inspection of all circuit breakers in the Eaton panel. Conducted GFCI/shock protection outlet and breaker testing to verify proper ground fault protection functionality. Tested all arc fault circuit interrupters to ensure fire protection systems were operating within specifications. Performed smoke and carbon monoxide detector maintenance including battery replacement and functional testing of ceiling-mounted units throughout the home.
Knightdale, NC 27545
Completed comprehensive tune-up service on two 4-year-old Lennox HVAC systems. Performed standard maintenance procedures including inspection of air handler components, capacitor testing, refrigerant line examination, electrical connections verification, and condensate drain line assessment. Documented system conditions with interior and exterior unit photography, noting all components operational at time of service with proper insulation and wiring connections intact.
Completed comprehensive tune-up service on two 4-year-old Lennox HVAC systems. Performed standard maintenance procedures including inspection of air handler components, capacitor testing, refrigerant line examination, electrical connections verification, and condensate drain line assessment. Documented system conditions with interior and exterior unit photography, noting all components operational at time of service with proper insulation and wiring connections intact.
Thomas M.
Thomas M. Checked in
Completed comprehensive tune-up service on two 4-year-old Lennox HVAC systems. Performed standard maintenance procedures including inspection of air handler components, capacitor testing, refrigerant line examination, electrical connections verification, and condensate drain line assessment. Documented system conditions with interior and exterior unit photography, noting all components operational at time of service with proper insulation and wiring connections intact.
Knightdale, NC 27545
# Electric Service Call Summary

Responded to nuisance tripping on circuit serving Ring doorbell, exterior lighting, and bedroom outlets. Upon inspection, discovered overloaded circuit with multiple high-draw devices on single breaker. 

Performed troubleshooting to isolate fault and determined circuit required reconfiguration. Installed new dedicated circuit for Ring doorbell and exterior lighting to separate load from bedroom receptacles. Ran new wiring through wall cavity and installed additional electrical box. Terminated all connections per NEC standards with proper wire nuts and secured all conductors. Replaced damaged outlet in bedroom with new tamper-resistant receptacle and repaired drywall opening around electrical box.

Verified all circuits operational with no tripping under normal load conditions. Tested Ring doorbell, exterior lights, and bedroom outlets independently to confirm proper voltage and functionality. Reset breaker panel and confirmed all connections tight and
# Electric Service Call Summary

Responded to nuisance tripping on circuit serving Ring doorbell, exterior lighting, and bedroom outlets. Upon inspection, discovered overloaded circuit with multiple high-draw devices on single breaker. 

Performed troubleshooting to isolate fault and determined circuit required reconfiguration. Installed new dedicated circuit for Ring doorbell and exterior lighting to separate load from bedroom receptacles. Ran new wiring through wall cavity and installed additional electrical box. Terminated all connections per NEC standards with proper wire nuts and secured all conductors. Replaced damaged outlet in bedroom with new tamper-resistant receptacle and repaired drywall opening around electrical box.

Verified all circuits operational with no tripping under normal load conditions. Tested Ring doorbell, exterior lights, and bedroom outlets independently to confirm proper voltage and functionality. Reset breaker panel and confirmed all connections tight and
Jeff L.
Jeff L. Checked in
# Electric Service Call Summary Responded to nuisance tripping on circuit serving Ring doorbell, exterior lighting, and bedroom outlets. Upon inspection, discovered overloaded circuit with multiple high-draw devices on single breaker. Performed troubleshooting to isolate fault and determined circuit required reconfiguration. Installed new dedicated circuit for Ring doorbell and exterior lighting to separate load from bedroom receptacles. Ran new wiring through wall cavity and installed additional electrical box. Terminated all connections per NEC standards with proper wire nuts and secured all conductors. Replaced damaged outlet in bedroom with new tamper-resistant receptacle and repaired drywall opening around electrical box. Verified all circuits operational with no tripping under normal load conditions. Tested Ring doorbell, exterior lights, and bedroom outlets independently to confirm proper voltage and functionality. Reset breaker panel and confirmed all connections tight and
Knightdale, NC 27545
Review
Excellent we work!! Will refer people to your company. Thanks for the wonderful people you sent to my brother's home. Happy Easter.
George - Knightdale, NC 27545
Completed comprehensive electrical service upgrade including installation of new 200 amp meter base and 200 amp interior main breaker panel with all new circuit breakers and copper busbars. Replaced all devices throughout home with properly grounded switches, child-safe outlets, new cover plates, and four dimmer switches. Installed GFCI-protected outlets in kitchen (2), garage (1), downstairs bathroom (1), dining room (1), and upstairs bathrooms (2) per code requirements for areas within 6 feet of water sources. Replaced burnt electrical box in wall with new junction box. Extended smoke detector circuit and installed three hardwired smoke detectors in bedrooms with fire protection breaker. Added new combination smoke and carbon monoxide detector on second floor. Installed new GFCI breaker for spa circuit. Established proper grounding system with two ground rods and bonded gas line to electrical system per NEC requirements. Obtained necessary permit for electrical work performed. All in
Completed comprehensive electrical service upgrade including installation of new 200 amp meter base and 200 amp interior main breaker panel with all new circuit breakers and copper busbars. Replaced all devices throughout home with properly grounded switches, child-safe outlets, new cover plates, and four dimmer switches. Installed GFCI-protected outlets in kitchen (2), garage (1), downstairs bathroom (1), dining room (1), and upstairs bathrooms (2) per code requirements for areas within 6 feet of water sources. Replaced burnt electrical box in wall with new junction box. Extended smoke detector circuit and installed three hardwired smoke detectors in bedrooms with fire protection breaker. Added new combination smoke and carbon monoxide detector on second floor. Installed new GFCI breaker for spa circuit. Established proper grounding system with two ground rods and bonded gas line to electrical system per NEC requirements. Obtained necessary permit for electrical work performed. All in
Jeff L.
Jeff L. Checked in
Completed comprehensive electrical service upgrade including installation of new 200 amp meter base and 200 amp interior main breaker panel with all new circuit breakers and copper busbars. Replaced all devices throughout home with properly grounded switches, child-safe outlets, new cover plates, and four dimmer switches. Installed GFCI-protected outlets in kitchen (2), garage (1), downstairs bathroom (1), dining room (1), and upstairs bathrooms (2) per code requirements for areas within 6 feet of water sources. Replaced burnt electrical box in wall with new junction box. Extended smoke detector circuit and installed three hardwired smoke detectors in bedrooms with fire protection breaker. Added new combination smoke and carbon monoxide detector on second floor. Installed new GFCI breaker for spa circuit. Established proper grounding system with two ground rods and bonded gas line to electrical system per NEC requirements. Obtained necessary permit for electrical work performed. All in
Knightdale, NC 27545
Responded to sales inquiry for replacement options on aging residential air conditioning system installed in 2008. Conducted exterior inspection of single-zone condensing unit located on concrete pad at side of residence. Evaluated overall condition of equipment including cabinet integrity, refrigerant line insulation deterioration, and electrical disconnect components. Documented existing system with photographs showing weathered line set insulation and general wear consistent with 16-year-old equipment. Discussed replacement options and system upgrade recommendations with homeowner based on current equipment age and concerns about declining performance.
Responded to sales inquiry for replacement options on aging residential air conditioning system installed in 2008. Conducted exterior inspection of single-zone condensing unit located on concrete pad at side of residence. Evaluated overall condition of equipment including cabinet integrity, refrigerant line insulation deterioration, and electrical disconnect components. Documented existing system with photographs showing weathered line set insulation and general wear consistent with 16-year-old equipment. Discussed replacement options and system upgrade recommendations with homeowner based on current equipment age and concerns about declining performance.
Joe B.
Joe B. Checked in
Responded to sales inquiry for replacement options on aging residential air conditioning system installed in 2008. Conducted exterior inspection of single-zone condensing unit located on concrete pad at side of residence. Evaluated overall condition of equipment including cabinet integrity, refrigerant line insulation deterioration, and electrical disconnect components. Documented existing system with photographs showing weathered line set insulation and general wear consistent with 16-year-old equipment. Discussed replacement options and system upgrade recommendations with homeowner based on current equipment age and concerns about declining performance.
Knightdale, NC 27545
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Tim D.
Tim D. Checked in
# Service Call Summary Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage. ## Work Performed Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Knightdale, NC 27545
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Tim D.
Tim D. Checked in
# Service Call Summary Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage. ## Work Performed Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Knightdale, NC 27545
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Tim D.
Tim D. Checked in
# Service Call Summary Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage. ## Work Performed Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Knightdale, NC 27545
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
# Service Call Summary

Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage.

## Work Performed

Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Tim D.
Tim D. Checked in
# Service Call Summary Responded to electrical emergency where homeowner experienced blue arcing when plugging in device in office, resulting in multiple outlets becoming inoperative on the circuit. Breaker had been shut off by customer to prevent further damage. ## Work Performed Conducted comprehensive electrical inspection of affected office circuit and main electrical panel. Examined panel interior and identified circuit breakers serving the compromised office area. Documented existing electrical panel configuration showing proper wire connections to breakers and bus bars. Inspected main distribution panel with dual rows of circuit breakers, noting copper conduit entry points and wire routing throughout the system. Evaluated all visible electrical connections, terminals, and breaker conditions for signs of damage, overheating, or deterioration related to the arcing event. Photographed panel interior showing breaker arrangement, wire connections, and overall panel condition for s
Knightdale, NC 27545
Responded to service call for AC breaker repeatedly tripping on a second floor HVAC unit in a 2022 home. Performed diagnostic testing with clamp meter in the electrical panel, measuring 245.0 volts to the circuit. Inspected the disconnect switch in the attic, which was properly installed with appropriate conduit and connections.
Responded to service call for AC breaker repeatedly tripping on a second floor HVAC unit in a 2022 home. Performed diagnostic testing with clamp meter in the electrical panel, measuring 245.0 volts to the circuit. Inspected the disconnect switch in the attic, which was properly installed with appropriate conduit and connections.
Charlie B.
Charlie B. Checked in
Responded to service call for AC breaker repeatedly tripping on a second floor HVAC unit in a 2022 home. Performed diagnostic testing with clamp meter in the electrical panel, measuring 245.0 volts to the circuit. Inspected the disconnect switch in the attic, which was properly installed with appropriate conduit and connections.
Knightdale, NC 27545