0% Financing for 60 Months on Select HVAC Systems
financing Special Offers Call Us Book Online

Dunn, NC HVAC & Electrical

green-stars

Dunn's Trusted Source For HVAC & Electrical Excellence

Dunn homeowners have depended on us for heating, cooling, and electrical services since 2005, and we've earned that trust through consistent quality and straightforward dealings.

This area's weather demands air conditioners that can handle intense summer heat and heating systems ready when temperatures drop. Your home also needs electrical service that meets today's power demands while keeping your family safe. We take care of all of it—AC breakdowns, furnace tune-ups, panel upgrades, wiring, and more.

Need help with your home's comfort or safety?

Call 919-887-8284 today for all your HVAC and electrical service needs or contact us online with any questions.

Serving Dunn Neighborhoods

We serve Dunn homeowners in:

  • Westfield

  • Briarwood

  • Glenfield

  • North Park

  • South Dunn residential areas

  • Properties near Tyler Park

  • Homes along Erwin Road and NC-421

Given Dunn’s exposure to storm systems, whole home generator installation is especially common in these areas.

Why Choose Dawson's Electrical & Air?

When you call us, you get technicians who arrive on time, diagnose issues correctly, and explain everything without confusing jargon. We quote prices before starting work, and that's exactly what you pay. No hidden fees, no pressure to buy things you don't need—just honest HVAC and electrical service from professionals who care about doing the job right.

See what your neighbors are saying about our service below! 

Recent Jobs and Reviews in Dunn, NC

Job Locations and Reviews

Responded to service call for loss of power to hygiene chair outlet in commercial facility. Upon investigation, located affected outlet in utility compartment alongside HVAC equipment and refrigerant lines. Tested outlet, identified power loss issue, and restored electrical service to the circuit. Outlet is now functioning properly and hygiene chair equipment has been returned to normal operation.
Responded to service call for loss of power to hygiene chair outlet in commercial facility. Upon investigation, located affected outlet in utility compartment alongside HVAC equipment and refrigerant lines. Tested outlet, identified power loss issue, and restored electrical service to the circuit. Outlet is now functioning properly and hygiene chair equipment has been returned to normal operation.
Tim D.
Tim D. Checked in
Responded to service call for loss of power to hygiene chair outlet in commercial facility. Upon investigation, located affected outlet in utility compartment alongside HVAC equipment and refrigerant lines. Tested outlet, identified power loss issue, and restored electrical service to the circuit. Outlet is now functioning properly and hygiene chair equipment has been returned to normal operation.
Dunn, NC 28334
Dunn, NC - Installed dedicated electrical circuit for pool equipment at residential property built in 2020. Ran new circuit line from main electrical panel located in garage to exterior pool equipment location, ensuring proper amperage and code compliance for safe pool operation. Reviewed site plan documentation and captured photos of completed installation for service records.
Curtis E.
Curtis E. Checked in
Installed dedicated electrical circuit for pool equipment at residential property built in 2020. Ran new circuit line from main electrical panel located in garage to exterior pool equipment location, ensuring proper amperage and code compliance for safe pool operation. Reviewed site plan documentation and captured photos of completed installation for service records.
Dunn, NC 28334
Responded to electrical safety concern at 1948 residential property regarding potential fire hazard in attic wiring. Performed thorough inspection of attic space and existing electrical panel assembly, documenting conditions with photographs. Assessed exposed wiring running across attic floor, deteriorated insulation near electrical components, and overall state of electrical distribution system including industrial-grade contactor, circuit breakers, and copper cable connections to determine necessary rewiring scope and safety recommendations.
Responded to electrical safety concern at 1948 residential property regarding potential fire hazard in attic wiring. Performed thorough inspection of attic space and existing electrical panel assembly, documenting conditions with photographs. Assessed exposed wiring running across attic floor, deteriorated insulation near electrical components, and overall state of electrical distribution system including industrial-grade contactor, circuit breakers, and copper cable connections to determine necessary rewiring scope and safety recommendations.
Curtis E.
Curtis E. Checked in
Responded to electrical safety concern at 1948 residential property regarding potential fire hazard in attic wiring. Performed thorough inspection of attic space and existing electrical panel assembly, documenting conditions with photographs. Assessed exposed wiring running across attic floor, deteriorated insulation near electrical components, and overall state of electrical distribution system including industrial-grade contactor, circuit breakers, and copper cable connections to determine necessary rewiring scope and safety recommendations.
Dunn, NC 28334
Installed new GFCI receptacle in weatherproof exterior enclosure for dedicated dehumidifier circuit at 1930s-era residence. Verified proper humidity monitoring equipment connection and tested electrical protection device for correct operation, confirming 30.9% RH reading on connected ProSelect dehumidifier unit model PSGCV-V19IMS.
Installed new GFCI receptacle in weatherproof exterior enclosure for dedicated dehumidifier circuit at 1930s-era residence. Verified proper humidity monitoring equipment connection and tested electrical protection device for correct operation, confirming 30.9% RH reading on connected ProSelect dehumidifier unit model PSGCV-V19IMS.
Charlie B.
Charlie B. Checked in
Installed new GFCI receptacle in weatherproof exterior enclosure for dedicated dehumidifier circuit at 1930s-era residence. Verified proper humidity monitoring equipment connection and tested electrical protection device for correct operation, confirming 30.9% RH reading on connected ProSelect dehumidifier unit model PSGCV-V19IMS.
Dunn, NC 28334
Responded to warranty callback for recently installed Amana HVAC system experiencing inconsistent temperatures throughout home, inadequate upstairs cooling, and airflow concerns. Inspected outdoor condensing unit and verified proper installation on concrete pad with appropriate electrical connections. Accessed attic space to evaluate ductwork distribution system and insulated flex duct runs serving upper level zones. Completed deferred installation task by installing plywood support base for secondary unit to ensure proper equipment stability and prevent future operational issues. Documented equipment condition and installation with photographic evidence showing condensing unit positioning and attic ductwork configuration for warranty records.
Responded to warranty callback for recently installed Amana HVAC system experiencing inconsistent temperatures throughout home, inadequate upstairs cooling, and airflow concerns. Inspected outdoor condensing unit and verified proper installation on concrete pad with appropriate electrical connections. Accessed attic space to evaluate ductwork distribution system and insulated flex duct runs serving upper level zones. Completed deferred installation task by installing plywood support base for secondary unit to ensure proper equipment stability and prevent future operational issues. Documented equipment condition and installation with photographic evidence showing condensing unit positioning and attic ductwork configuration for warranty records.
Keith M.
Keith M. Checked in
Responded to warranty callback for recently installed Amana HVAC system experiencing inconsistent temperatures throughout home, inadequate upstairs cooling, and airflow concerns. Inspected outdoor condensing unit and verified proper installation on concrete pad with appropriate electrical connections. Accessed attic space to evaluate ductwork distribution system and insulated flex duct runs serving upper level zones. Completed deferred installation task by installing plywood support base for secondary unit to ensure proper equipment stability and prevent future operational issues. Documented equipment condition and installation with photographic evidence showing condensing unit positioning and attic ductwork configuration for warranty records.
Dunn, NC 28334
Replaced 18-year-old blower motor in customer's furnace system that customer had previously attempted to service themselves. Conducted visual inspection of the complete HVAC system including outdoor condenser unit to verify proper operation following motor replacement.
Replaced 18-year-old blower motor in customer's furnace system that customer had previously attempted to service themselves. Conducted visual inspection of the complete HVAC system including outdoor condenser unit to verify proper operation following motor replacement.
Aaron P.
Aaron P. Checked in
Replaced 18-year-old blower motor in customer's furnace system that customer had previously attempted to service themselves. Conducted visual inspection of the complete HVAC system including outdoor condenser unit to verify proper operation following motor replacement.
Dunn, NC 28334
Responded to customer complaint of kitchen lights flickering and dimming when oven is in use. Conducted inspection of electrical panel and utility meter, documenting system with photos. Determined issue was related to voltage fluctuation during high-demand appliance operation, likely due to undersized circuit or loose connection. Corrected problem by tightening connections and verifying proper load distribution.
Responded to customer complaint of kitchen lights flickering and dimming when oven is in use. Conducted inspection of electrical panel and utility meter, documenting system with photos. Determined issue was related to voltage fluctuation during high-demand appliance operation, likely due to undersized circuit or loose connection. Corrected problem by tightening connections and verifying proper load distribution.
Nick R.
Nick R. Checked in
Responded to customer complaint of kitchen lights flickering and dimming when oven is in use. Conducted inspection of electrical panel and utility meter, documenting system with photos. Determined issue was related to voltage fluctuation during high-demand appliance operation, likely due to undersized circuit or loose connection. Corrected problem by tightening connections and verifying proper load distribution.
Dunn, NC 28334
Performed preventative maintenance on a 5-year-old HVAC system. Inspected the dual-run capacitor (40+5μF) which showed signs of normal wear, and conducted amperage testing using a Fluke 374 FC clamp meter to verify proper electrical operation. System was functioning within specifications after service.
Performed preventative maintenance on a 5-year-old HVAC system. Inspected the dual-run capacitor (40+5μF) which showed signs of normal wear, and conducted amperage testing using a Fluke 374 FC clamp meter to verify proper electrical operation. System was functioning within specifications after service.
Connor G.
Connor G. Checked in
Performed preventative maintenance on a 5-year-old HVAC system. Inspected the dual-run capacitor (40+5μF) which showed signs of normal wear, and conducted amperage testing using a Fluke 374 FC clamp meter to verify proper electrical operation. System was functioning within specifications after service.
Dunn, NC 28334
Completed preventative maintenance service on 2018 HVAC unit including comprehensive 80-point inspection. Performed standard maintenance tasks including outdoor coil cleaning and burner cleaning, with gas pressure adjustments as needed. Electrical system inspection conducted using Fluke 374 FC clamp meter with all components and circuit breaker connections verified to be functioning properly.
Completed preventative maintenance service on 2018 HVAC unit including comprehensive 80-point inspection. Performed standard maintenance tasks including outdoor coil cleaning and burner cleaning, with gas pressure adjustments as needed. Electrical system inspection conducted using Fluke 374 FC clamp meter with all components and circuit breaker connections verified to be functioning properly.
Connor G.
Connor G. Checked in
Completed preventative maintenance service on 2018 HVAC unit including comprehensive 80-point inspection. Performed standard maintenance tasks including outdoor coil cleaning and burner cleaning, with gas pressure adjustments as needed. Electrical system inspection conducted using Fluke 374 FC clamp meter with all components and circuit breaker connections verified to be functioning properly.
Dunn, NC 28334
Conducted replacement options consultation for 19-year-old HVAC system. Inspection revealed severely dust-clogged fan assembly and weathered exterior electrical connections. Discussed appropriate replacement units for elderly homeowners' needs and presented financing options for consideration, as their current system is disconnected with only attic heat strips functioning.
Conducted replacement options consultation for 19-year-old HVAC system. Inspection revealed severely dust-clogged fan assembly and weathered exterior electrical connections. Discussed appropriate replacement units for elderly homeowners' needs and presented financing options for consideration, as their current system is disconnected with only attic heat strips functioning.
Joe B.
Joe B. Checked in
Conducted replacement options consultation for 19-year-old HVAC system. Inspection revealed severely dust-clogged fan assembly and weathered exterior electrical connections. Discussed appropriate replacement units for elderly homeowners' needs and presented financing options for consideration, as their current system is disconnected with only attic heat strips functioning.
Dunn, NC 28334
Completed 32-point electrical system evaluation and panel maintenance, which included torquing connections, testing GFCI/Arc Fault protection devices, and performing smoke/CO2 detector maintenance with battery replacement. Observed signs of aging in the electrical panel including some corrosion where conduits enter the panel and heat discoloration on metal components, but all systems were verified to be functioning properly after service.
Completed 32-point electrical system evaluation and panel maintenance, which included torquing connections, testing GFCI/Arc Fault protection devices, and performing smoke/CO2 detector maintenance with battery replacement. Observed signs of aging in the electrical panel including some corrosion where conduits enter the panel and heat discoloration on metal components, but all systems were verified to be functioning properly after service.
Charlie B.
Charlie B. Checked in
Completed 32-point electrical system evaluation and panel maintenance, which included torquing connections, testing GFCI/Arc Fault protection devices, and performing smoke/CO2 detector maintenance with battery replacement. Observed signs of aging in the electrical panel including some corrosion where conduits enter the panel and heat discoloration on metal components, but all systems were verified to be functioning properly after service.
Dunn, NC 28334
Completed comprehensive preventative maintenance on HVAC system, performing 80-point inspection including cleaning of outdoor coils, burner cleaning, and gas pressure adjustments as needed. Inspected electrical panel connections and verified proper operation of ecobee smart thermostat (currently set at 70°F with actual temperature reading of 65°F).
Completed comprehensive preventative maintenance on HVAC system, performing 80-point inspection including cleaning of outdoor coils, burner cleaning, and gas pressure adjustments as needed. Inspected electrical panel connections and verified proper operation of ecobee smart thermostat (currently set at 70°F with actual temperature reading of 65°F).
Connor G.
Connor G. Checked in
Completed comprehensive preventative maintenance on HVAC system, performing 80-point inspection including cleaning of outdoor coils, burner cleaning, and gas pressure adjustments as needed. Inspected electrical panel connections and verified proper operation of ecobee smart thermostat (currently set at 70°F with actual temperature reading of 65°F).
Dunn, NC 28334
Keith M.
Keith M. Checked in
Arrived to perform peace of mind service on unit less than one year-old. Checked cycled and tested all heating operations. Check reversing valve, defrost, and auxiliary heat function. Cleared drain line, tested all motors and capacitors. All motors and capacitors are within parameters. Refrigerate charge is correct. Tested airflow, and complete visual inspection of all components and coils. 24 x 24 filter inside the home looks like it could be replaced. All operations are a OK at this time. Thank you for trusting Dawsons with your heating and air needs.
Dunn, NC 28334
Keith M.
Keith M. Checked in
Customer states unit will not run in heat and only blows cold/cool air. Unit is a 10 year-old heat pump package unit with original ductwork. Found the system on a low pressure lockout. Initial visual inspection found drain line trap below grade with several indications. The unit is not draining properly. 1 to 2 inch waterline inside the unit confirms this. After hooking up gauges,Schrader valve core was leaking and will not seal/close. Recycled power and started unit in heating mode. Heating operations appear correct. Auxiliary heat and primary heating heat pump function all appear to be functional. The system is a 3 ton heat pump with approximately one and a half to 2 tons of ductwork. The return caller attached to this unit is a 14 inch duct and should be at least a 16 inch. It’s possible the system is oversized or the ductwork is considerably undersized. The compressor is drawing excessive amperage on startup. Manufacturers writing is 77 A and the compressor is drawing 95.6 A. Str
Dunn, NC 28334
Donovan G.
Donovan G. Checked in
Repair and residential ceiling fan
Dunn, NC 28334
Travis D.
Travis D. Checked in
Electrician providing whole home generator consultation
Dunn, NC 28334
Travis D.
Travis D. Checked in
Electrician installing smoke detectors and performing safety inspection
Dunn, NC 28334
Travis D.
Travis D. Checked in
Electricians installing wiring for recessed cans, lights, and outlets.
Dunn, NC 28334
Travis D.
Travis D. Checked in
Electrician repair open splice and checking ungrounded outlets
Dunn, NC 28334